Vulnerabilities (CVE)

Vendor filter

Siemens Subscribe

Product filter

Sinema Server Subscribe

Filter

7 total CVE
CVE Vendors Products Updated CVSS
CVE-2019-6575 1 Siemens 18 Simatic S7-1500 Software Controller, Simatic Wincc Runtime Advanced, Simatic Wincc Runtime Comfort and 15 more 2019-07-11 7.8
A vulnerability has been identified in SIMATIC CP443-1 OPC UA (All versions), SIMATIC ET 200 Open Controller CPU 1515SP PC2 (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22"...
CVE-2017-6865 1 Siemens 16 Pcs 7, Sinumerik 808d Programming Tool, Simatic Net Pc-software and 13 more 2019-03-21 6.1
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All...
CVE-2016-7165 1 Siemens 18 Simatic Wincc %28tia Portal%29, Simatic Wincc Runtime, Sinema Server and 15 more 2018-06-15 6.9
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7...
CVE-2016-6486 1 Siemens 1 Sinema Server 2016-11-28 7.2
Siemens SINEMA Server uses weak permissions for the application folder, which allows local users to gain privileges via unspecified vectors.
CVE-2014-2732 1 Siemens 1 Sinema Server 2015-10-08 5.0
Multiple directory traversal vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to access arbitrary files via HTTP traffic to port (1) 4999 or (2) 80.
CVE-2014-2733 1 Siemens 1 Sinema Server 2014-04-21 5.0
Siemens SINEMA Server before 12 SP1 allows remote attackers to cause a denial of service (web-interface outage) via crafted HTTP requests to port (1) 4999 or (2) 80.
CVE-2014-2731 1 Siemens 1 Sinema Server 2014-04-21 9.3
Multiple unspecified vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to execute arbitrary code via HTTP traffic to port (1) 4999 or (2) 80.